For simplicity and to be conservative the higher rate is often used for all applications.
Commercial bathroom exhaust requirements.
The illustration above demonstrates the use of a ceiling exhaust fan mounted in the rest room exhausting the stale air.
Bathrooms must have windows when this section is adopted by a community it essentially says that for venting purposes bathrooms must have windows that open.
Some signs of excessive uncontrolled bathroom moisture include.
The exhaust from a bathroom or kitchen in a residential dwelling shall not be considered to be a hazardous or noxious contaminant.
For ashrae s requirements for commercial restrooms.
Do they do it by the number of toilets or air changes per hour.
Where a source of contaminant is located within 10 feet 3048 mm horizontally of an intake opening such opening shall be located a minimum of 2 feet 610 mm below the contaminant source.
A commercial restroom will require air to be changed 8 12 times an hour depending on the size of the facility and your local code.
Local bathroom or kitchen fans that exhaust air outdoors and remove contaminants directly from the room where the fan is located also increase the outdoor air ventilation rate.
Bathroom exhaust fan venting code summary section r303 3.
Ashrae restroom exhaust requirement.
Every bathroom requires an openable window that provides at least 1 5 square ft of air flow area when open 2006 irc 303 3 or mechanical type ventilation.
In florida it is a minimum of 50 cfm per toilet or urinal.
Standard 2 1 2013 requires an exhaust rate of 0 cfm 3 s per ater closeturinal here long periods of heavy use are expected to occur e g restrooms in theatres schools and sports facilities and 0 cfm 2 s in other applications such as ofce buildings.
Mechanical exhaust is required and recirculation is prohibited except that recirculation shall be permitted where the resulting supply airstream consists of not more than 10 percent air recirculated from these spaces see section 403 2 1 items 2 and 4.
50 cfm intermittent or 20 cfm continuous operation 2006 irc 303 3x.
Ventilation in schools offices and commercial buildings.
Bathroom window condensation and frost forming on bathroom windows during freezing.
Limits the capacity of a home s two largest exhaust fans to a net total exhaust flow of 15 cfm 100 ft2.
This exhaust air can be routed either to the roof using ductwork and a roof vent or to the side of your building using ductwork and a hooded wall vent.
Stains thermal tracking or mold growth on bathroom walls and ceilings possibly also on bath vanities and cabinets.